Paul & Steve, What sort of lab readings does one get using UT7 to print a 21point neutral grayscale? Bob Frost. ----- Original Message ----- Steve, For comparison, here is a 21 point set of readings (i1 and MeasureTool) from the R2400 using Advanced B&W with the default settings of Neutral/Darker. 1 94.21 -0.20 -3.60 2 89.45 -0.02 -3.20 3 84.62 -0.01 -2.88 4 80.46 -0.03 -2.68 5 75.57 -0.07 -2.89 6 70.99 -0.35 -2.68 7 66.51 -0.10 -2.14 8 61.72 -0.30 -2.01 9 57.06 -0.53 -1.93 10 52.32 -0.44 -1.95 11 48.09 -0.49 -1.63 12 43.16 -0.58 -1.62 13 37.83 -0.36 -1.14 14 32.26 -0.40 -0.94 15 27.61 -0.41 -0.65 16 22.82 -0.27 -0.43 17 17.83 -0.18 -0.39 18 13.03 0.03 -0.35 19 8.57 0.21 -0.03 20 5.52 0.04 0.18 21 2.93 -0.07 -0.33 The cool shift is due to the paper (Premium Glossy) showing through the ink.
Message
Re: [Digital BW] Advanced B&W was Re: 4800 v. UT7 1600 dpi scans
2005-06-29 by Bob Frost