Yahoo Groups archive

Digital BW, The Print

Index last updated: 2026-04-28 22:56 UTC

Message

Brian and David was Re: [Digital BW] Profiling with Dedicated B&W Inks

2008-12-12 by Jon Cone

Hey Walker,

Go into the reference files of the MeasureTool and look at the text
format of the existing targets. It is not obvious how they organize
the data to target. But if you create a small one with more than one
row and column, you will get the idea.

You can pretty easily make any type of target you need that way.

Hope this helps. As I do not have a MeasureTool compatible target for
it. ColorPort saves XML and MeasureTool needs text...

Jon

PS  - losing you to color inks is going to be a very sad day. Do not
use too much C,M,Y



--- In DigitalBlackandWhiteThePrint@yahoogroups.com, Walker Blackwell
<forums@...> wrote:
>
> Jon. Do you have a MeasureTool TXT file for that 256 target? I am  
> working on a BW workflow that will let me match any hue value from any  
> BW printing process (Silver or Digital) with either a K3 ink setup or  
> K5 with LC LM Y, using custom RGB input profiles. I have some K3  
> matches done already for the 11880 . . .
> 
> This target would be useful for debugging . . .
> 
> all the best,
> Walker
> 
> 
> On Dec 12, 2008, at 12:33 PM, Jon Cone wrote:
> 
> > Paul,
> >
> > Does the Spyder read single patches or rows? I am under the impression
> > it reads rows or is semi-automated to eliminate human error. It would
> > seem the type on your target might get picked up by the reader unless
> > the software eliminates it. Human error is a bad bad thing in any form
> > of precision profiling.
> >
> > If it is a single patch reader I would think it would take about 20
> > minutes to accurately read 256 patches. Why am I in the dark about
> > this device????
> >
> > The 256 patch DTP70 target is here:
> > http://www.piezography.com/EyeOne-256-patches.tif
> >
> > The EyeOne target is here:
> > http://www.piezography.com/EyeOne-256-patches.tif
> >
> > I have targets also for the DTP-20, DTP-40, and the EyeOne iO, and
> > even the old Gretag SpectraScan (wonderful device but needs older
> > operating systems.)
> >
> > Jon
> >
> > --- In DigitalBlackandWhiteThePrint@yahoogroups.com, "pr_roark"
> > <pr_roark@> wrote:
> > >
> > > Jon,
> > >
> > > ...
> > > > Do you think that the Spyder software has enough documentation to
> > > > allow Brian to create his own 256 grayscale patch target,
> > > > measure it, and save the L data that makes sense in relation
> > > > to the target?
> > >
> > > Will a standard 256-Step grayscale test target like below work?
> > >
> > > http://www.paulroark.com/BW-Info/256-Step-GS.jpg
> > >
> > >
> > > Paul
> > > www.PaulRoark.com
> > >
> >
> >
> > 
> 
> 
> 
> [Non-text portions of this message have been removed]
>