Jerry wrote: >But how do you know what numbers to type in? There is definitely some trial and error. After printing a step wedge test file, scan it. Use levels to put the 0% and 100% where they should be. Then read the values of the other patches. If, for example, the 95% patch reads 97%, try putting a 94 in the 95% box of the Transfer Function. (It tends to overshoot.) Then print with it and see what happened. Don't expect to get the exact values all the way. If you make too many or too radical adjustments in the Transfer Function the ramp get ripply. So, go easy and slow, saving the files as you go, and marking the test prints so you can conclude after you've gone too far which made the best print. Paul > > > >But what about transfer curves? How do They work? > >What would they offer that the rgb curves wouldn't?
Message
Re: [Digital BW] 4 Paul Roark: MIS VM and Piezo Questions
2001-08-20 by Paul Roark
Attachments