David, before we continue: does this problem occur only with the combination of A-155 with A-154 ? Or does it occur even with a standalone A-155. If the A-155's have been modified earlier (for standalone mode) this modification has to be cancelled (i.e. undo). Please refer to page 16 of the A-154 manual and the attached document. Best regards Dieter Doepfer Doepfer Musikelektronik GmbH Email address: hardware@doepfer.de Web Site: www.doepfer.com > -----Ursprüngliche Nachricht----- > Von: Doepfer_a100@yahoogroups.com > [mailto:Doepfer_a100@yahoogroups.com]Im Auftrag von deastman2 > Gesendet: Donnerstag, 6. April 2006 09:54 > An: Doepfer_a100@yahoogroups.com > Betreff: [Doepfer_a100] A-154/dual A-155 combination false triggering > problem > > > I have an A-154 configured to control two A-155's. I've noticed that > for Trigger Rows 1&2 for both A-155's, some steps seem to generate > one or more extra, erroneous trigger pulses. I looked at the output > on a scope, and I see the following: > > Steps 1 and 5 show the main trigger pulse, followed by three very low- > level pulses at the spots where steps 2, 3, and 5 would be. > > Steps 3 and 7 show the main trigger pulse, followed by one very low- > level pulse at the spot where steps 4 and 8 would be. > > Steps 2, 4, 6, and 8 function normally. > > These extra pulses are strong enough to at least partially trigger an > envelope generator controlling a VCA with an osc feeding into it. > For example, with all steps/rows on both sequencers in the 'off' > position, except for row 1/step 1 on one seq, I get an envelope > trigger at step one, followed by a lower-level trigger at step 2 (and > in theory, it probably triggers again steps 3 and 5, if the envelope > was set properly). These extra pulses stay in sync when I adjust the > clock rate. > > I had this same problem when I first got the sequencers back in > January, except at that time, row 3 also had the same problem. With > only one A-155 connected to the A-154, there is no problem. Either A- > 155 will function properly with the A-154, but once they are chained > together, the problem appears. I sent the A-154 back to Analogue > Haven for replacement, and the new one they sent me worked fine for a > couple of months, until yesterday when this malfunction resurfaced. > > Other relevant information: The connecting cables were replaced as > well. The sequencers are all powered by a single new PSU2. Aside > from the A-100, there is nothing else in close proximity which could > be causing interference. > > I'm hoping there is a simple answer other than shipping back more > modules... > > Thanks, > David > > > > > > > > > Yahoo! Groups Links > > > [Non-text portions of this message have been removed]
Message
AW: [Doepfer_a100] A-154/dual A-155 combination false triggering problem
2006-04-06 by Dieter Doepfer
Attachments
- No local attachments were found for this message.