Dieter, If the A-155's are configured for standalone operation, they work correctly. Also, if I put the A-154 in manual mode and clock the first A-155 with an LFO, there is no problem. But if I use an LFO as an Ext. Clock source for the A-154, the problem appears, just like using the internal clock. --- In Doepfer_a100@yahoogroups.com, "Dieter Doepfer" <hardware@...> wrote: > > David, > > before we continue: does this problem occur only with the combination of > A-155 with A-154 ? Or does it occur even with a standalone A-155. If the > A-155's have been modified earlier (for standalone mode) this modification > has to be cancelled (i.e. undo). Please refer to page 16 of the A- 154 manual > and the attached document. > > Best regards > Dieter Doepfer > Doepfer Musikelektronik GmbH > Email address: hardware@... > Web Site: www.doepfer.com > > > > > -----Ursprüngliche Nachricht----- > > Von: Doepfer_a100@yahoogroups.com > > [mailto:Doepfer_a100@yahoogroups.com]Im Auftrag von deastman2 > > Gesendet: Donnerstag, 6. April 2006 09:54 > > An: Doepfer_a100@yahoogroups.com > > Betreff: [Doepfer_a100] A-154/dual A-155 combination false triggering > > problem > > > > > > I have an A-154 configured to control two A-155's. I've noticed that > > for Trigger Rows 1&2 for both A-155's, some steps seem to generate > > one or more extra, erroneous trigger pulses. I looked at the output > > on a scope, and I see the following: > > > > Steps 1 and 5 show the main trigger pulse, followed by three very low- > > level pulses at the spots where steps 2, 3, and 5 would be. > > > > Steps 3 and 7 show the main trigger pulse, followed by one very low- > > level pulse at the spot where steps 4 and 8 would be. > > > > Steps 2, 4, 6, and 8 function normally. > > > > These extra pulses are strong enough to at least partially trigger an > > envelope generator controlling a VCA with an osc feeding into it. > > For example, with all steps/rows on both sequencers in the 'off' > > position, except for row 1/step 1 on one seq, I get an envelope > > trigger at step one, followed by a lower-level trigger at step 2 (and > > in theory, it probably triggers again steps 3 and 5, if the envelope > > was set properly). These extra pulses stay in sync when I adjust the > > clock rate. > > > > I had this same problem when I first got the sequencers back in > > January, except at that time, row 3 also had the same problem. With > > only one A-155 connected to the A-154, there is no problem. Either A- > > 155 will function properly with the A-154, but once they are chained > > together, the problem appears. I sent the A-154 back to Analogue > > Haven for replacement, and the new one they sent me worked fine for a > > couple of months, until yesterday when this malfunction resurfaced. > > > > Other relevant information: The connecting cables were replaced as > > well. The sequencers are all powered by a single new PSU2. Aside > > from the A-100, there is nothing else in close proximity which could > > be causing interference. > > > > I'm hoping there is a simple answer other than shipping back more > > modules... > > > > Thanks, > > David > > > > > > > > > > > > > > > > > > Yahoo! Groups Links > > > > > > > > > [Non-text portions of this message have been removed] >
Message
Re: A-154/dual A-155 combination false triggering problem
2006-04-06 by deastman2
Attachments
- No local attachments were found for this message.