2006-04-26 by Dieter Doepfer

OK, I'll check this with an A-111 and A-113. But it may take a few days as
we are very busy with testing and modifying the BBD modules as the customers
are waiting anxiously for their modules.

Best wishes
Dieter Doepfer

> -----Ursprüngliche Nachricht-----
> Von: Doepfer_a100@yahoogroups.com
> [mailto:Doepfer_a100@yahoogroups.com]Im Auftrag von vliesgaard
> Gesendet: Mittwoch, 26. April 2006 07:37
> An: Doepfer_a100@yahoogroups.com
> Betreff: [Doepfer_a100] Re: A-113 input sencetivity/tracking problems
>
>
> --- In Doepfer_a100@yahoogroups.com, "Dieter Doepfer" <hardware@...>
> wrote:
> >
> > Dirk,
> >
> > does this problem occur with the A-111 only or even with A-110? And
> are you
> > sure that you shortened C10 (not C9, C9 is responsible for AC
> coupling of
> > the sawtooth) ?
> >
> > Best wishes
> > Dieter Doepfer
> >
>
> Hi,
>
> It only occurs with the A-111 pulse output.
> I don't have a A-110, but the A-113 works as expected with Roland
> System 100 vco's, Analoge Systems vco's/lfo's and the pulse output of
> the A-154 sequenser controler.
>
> I shorted both C's, just to make sure, and it helps a lot.
> But the A-113 still has problems tracking low frequenty's.
>
> Greetings Dirk.
>
>
>
>
>
>
>
>