Yahoo Groups archive

Doepfer

Index last updated: 2026-04-29 00:15 UTC

Message

A-188-1 with 128 and 4096 stages

2006-04-26 by Dieter Doepfer

Because we had some inquiries I have to point out that it is not possible to
order a modified module of the first two series and exchange it later for a
non-modified module from the third series (~June 2006). If you want to have
an A-188-1 with  128, 256 or 4096 stages without the "DIY modification" I
ask you to wait until June. Please refer to my message from April 11, 2006.
Same as for the A-188-1 with 4096 stages (MN3005) applies to the A-188-1
with 128 stages (MN3006)! Only the modules with 256, 512, 1024 and 2048
stages can be manufactured without that ugly DIY mods.

Best wishes
Dieter Doepfer

> -----Ursprüngliche Nachricht-----
> Von: Doepfer_a100@yahoogroups.com
> [mailto:Doepfer_a100@yahoogroups.com]Im Auftrag von vliesgaard
> Gesendet: Mittwoch, 26. April 2006 07:37
> An: Doepfer_a100@yahoogroups.com
> Betreff: [Doepfer_a100] Re: A-113 input sencetivity/tracking problems
>
>
> --- In Doepfer_a100@yahoogroups.com, "Dieter Doepfer" <hardware@...>
> wrote:
> >
> > Dirk,
> >
> > does this problem occur with the A-111 only or even with A-110? And
> are you
> > sure that you shortened C10 (not C9, C9 is responsible for AC
> coupling of
> > the sawtooth) ?
> >
> > Best wishes
> > Dieter Doepfer
> >
>
> Hi,
>
> It only occurs with the A-111 pulse output.
> I don't have a A-110, but the A-113 works as expected with Roland
> System 100 vco's, Analoge Systems vco's/lfo's and the pulse output of
> the A-154 sequenser controler.
>
> I shorted both C's, just to make sure, and it helps a lot.
> But the A-113 still has problems tracking low frequenty's.
>
> Greetings Dirk.
>
>
>
>
>
>
>
>
> Yahoo! Groups Links
>
>
>
>
>
>

Attachments

Move to quarantaine

This moves the raw source file on disk only. The archive index is not changed automatically, so you still need to run a manual refresh afterward.