2006-06-26 by ilanode

Hello Dan, Doepfer LFO-modules have no level controll for the output 
but most (if not each) have at least one input with a level control 
(attentuator). The VCFs have usually one input without attentuator 
(e.g. A122: CV1 for an 1/V response) and another one with 
attentuator (e.g. CV2 for those CVs which does not need to comply 
with the 1/V standard). Regards, Ingo (not selfoscilating)

--- In Doepfer_a100@yahoogroups.com, "danfarmer19732003" 
<danfarmer@...> wrote:
>
> Hi Ingo... when you say...
> 
> "you can simply attenuate the lfo output, that would be the 
simplest 
> solution."
> 
> What exactly do you mean? All I see on my LFO's is a rate knob 
that 
> controls the rate of the LFO. Can you give me an example of how to 
> attenuate the output?
> 
> 
> 
> >
> > 
> > hello dan,
> > 
> > you can simply attenuate the lfo output,
> > that would be the simplest solution.
> > 
> > the more elaborated solution would be the use of
> > one or two a172 max/min modules together with an
> > a176 voltage source, thats what i'm doing quite often.
> > 
> > best wishes
> > 
> > ingo
> > 
> > 
> > 
> > --- In Doepfer_a100@yahoogroups.com, "danfarmer19732003" 
> > <danfarmer@> wrote:
> > >
> > > Hi guys... I'm looking for what I might call a range limiter 
for 
> my 
> > > LFOs.
> > > 
> > > What I want to do is limit the range of the LFO. For example, 
if 
> > I'm 
> > > controlling the cutoff filter with the LFO I do not want the 
> filter 
> > to 
> > > close the filter 100%, I just still want some sound(s) to come 
> > through. 
> > > I'm finding that as it is right now, there is no EFFECT AMOUNT 
> > control 
> > > on the LFO's it just does a straight 0-100% range.
> > > 
> > > The opposite is true as well, in some case where I do not want 
> 100% 
> > of 
> > > the sounds to come through either. Meaning that I do not want 
the 
> > LFO 
> > > opening up the cutoff filter 100%.... again some king of 
EFFECT 
> > AMOUNT 
> > > control would be useful to me.
> > > 
> > > Can the Deopfer A-136 do this? If not what other module can? I 
> was 
> > > thinking if I routed the LFO through a filter and if that 
filter 
> > had 
> > > bandpass, that that might do what I want.
> > >
> >
>

Attachments