Re: A163 Question?

2006-12-09 by bellenger_a

Hello Phil


Then I guess you read the answers under here from Dieter and Ingo...

CV i knob is equipped with POLARIZER....


Best


Alexandre



--- In Doepfer_a100@yahoogroups.com, "doctorvague" <phil-brown@...> wrote:
>
> I'm having the exact same problem as you describe Alexandre. Anything I plug into the 
CV 
> input of the 163 seems to bypass the CV attenuator like it is not even there. I just 
received 
> this system about 2 weeks ago and am not experiencing any other oddities except this. 
It 
> seems broken and my next step was to pull it out and see if something was 
shortedoutthat 
> I could spot easily - then I saw your post here.... A bad run of modules or a bad part 
> perhaps?
> Ideas anyone?
> Phil
> 
> --- In Doepfer_a100@yahoogroups.com, "bellenger_a" <bellenger_a@> wrote:
> >
> > HELLO
> > 
> > I just recieve A163... Something bizarre : when I put in cable to CV In (LFO sine for 
ex.), 
> > with both knobs totally ccw to 0 position.... the CV DOES AFFECT the coming in signal 
> (PLL 
> > rect. for ex.)
> > 
> > Is that BIZARRE OR NOT?
> > 
> > and then if I turn on the knobs they do work...
> > 
> > 
> > OTHERWISE A188-1 together with A106-1 is JUST QUITE INCREDIBLE OPTIONS....
> > 
> > 
> > Best,
> > 
> > 
> > Alexandre
> >
>

Attachments