Message

AW: [Doepfer_a100] A-155 - how to start on first step after reset?

2007-06-12 by hardware@doepfer.de

> Hi,
>
> playing with my A-155 the last days the problem/question arose again:
> If I do stop and reset. The reset jumps to step 1. The first clock after
> start makes it to advance to step 2 with the first note.
>
> Ok, I could think step 2 as first, but if I want to use the reset while
> the sequence is running, it would not reset to 2 (the intended first
> step), but to 1 (the technical real first step).
>
> So what I need is some trick which suppresses the clock to advance the
> counter with the first step.
> I know how to do this by some logic and flip-flops, but I have no idea
> how to achieve this with the means of the A-100 (and no, I do not want
> to use a lot of A-166 to create flipflops).
>
> Florian

The problem has been solved with the A-154 as controller for the A-155. A
reset "prepares" the internal logic for the "real" reset. The advance to
step 1 takes place at the next clock pulse. But we already got some
complaints about this behaviour as the people are used to the behaviour
where a reset causes an immediate jump to step 1.

Best wishes
Dieter