Yahoo Groups archive

Doepfer

Index last updated: 2026-04-29 00:15 UTC

Message

AW: AW: [Doepfer_a100] A-155 - how to start on first step after reset?

2007-06-13 by hardware@doepfer.de

I will see if there is a chance to add another switch to the A-154 but from
the first glance this will be a problem as there is no space at the front
panel left and all port inputs of the microcontroller are used. Maybe a
special control setting (e.g. first step fully clockwise) could be used to
trigger the second reset mode (i.e. immediate reset to step 1).

Best wishes
Dieter Doepfer


> -----Ursprüngliche Nachricht-----
> Von: Doepfer_a100@yahoogroups.com
> [mailto:Doepfer_a100@yahoogroups.com]Im Auftrag von verstaerker
> Gesendet: Mittwoch, 13. Juni 2007 09:37
> An: hardware@doepfer.de
> Betreff: Re: AW: [Doepfer_a100] A-155 - how to start on first step after
> reset?
>
>
> i think it's a bit confusing for users that both devices react differently
>
> what about a switch on both devices to switch between both behaviours
>
> >  The problem has been solved with the A-154 as controller for
> the A-155. A
> >  reset "prepares" the internal logic for the "real" reset. The
> advance to
> >  step 1 takes place at the next clock pulse. But we already got some
> >  complaints about this behaviour as the people are used to the behaviour
> >  where a reset causes an immediate jump to step 1.
> >
> >  Best wishes
> >  Dieter
> >
> >
> >
> >
> >
>
>
> --
> Mit freundlichen Grüßen
> verstaerker
> mailto:verstaerker@verstaerker-music.net
>
>
>
>
> Yahoo! Groups Links
>
>
>

Attachments

Move to quarantaine

This moves the raw source file on disk only. The archive index is not changed automatically, so you still need to run a manual refresh afterward.