Hi Sam, Check that all the socketted ICs are well seated, especially the small 8-pin DIL at the top edge of the board, marked '24C16' - that is an EEPROM chip and very likely is where such information is stored when the power is off. (The square chip below it, 44 pins, is the processor, and left of that, another DIL, with 28 pins, is the ROM chip holding the software. The only other socketted chip on mine is a MAX531, a digital-to-analog converter, so it is unlikely to be that causing the problem.) If that doesn't fix it, then you're going to need some proper help I suspect! Tim --- In Doepfer_a100@yahoogroups.com, "sam" <sams2cats@...> wrote: > > hello > i'm finding that every time i turn on my modular i have to reset the scale on my a190 > interface. i have saved it using the procedure outlined in the manual but still everytime i > need to reset it. there was a time when it would periodically retain the settings after > powering down but now it never seems to. any idea what the problem could be? it's starting > to drive me nuts and i am a patient man. > thanks! > sam >
Message
Re: a190 problems
2007-10-12 by Tim Stinchcombe