> First of all please check if there are envelope signals for the outputs 2, 3 > and 4 (observable at the LEDs of the units 2, 3 and 4). YES THEY ALL WORK... each envelop works and lits up OK... >The solder point labelled "JP4" of > all four boards (located behind the control "Mix Polarizer" at the edge of > the board) should be connected with a blank wire. If this connection is > missing only envelope output #1 appears at the mix output. well there is some kinda thin metal bar (blank wire I guess as you said) joining all this JP4 points... and... in fact, I think maybe this blank wire isnt totally well soldered to the first board in fact... which then might cause no contact... I dont know really if that is what's wrong, I will bring back the module to MESI asap... LAST MINUTE : well after I slightly touched the blank wire and plug the module back, its now working... Dieter, would the guarantee goes off if I ask MESI to solder this again for me? thanks for yr attention, /a/ > > Best wishes > Dieter Doepfer >
Message
Re: A143-1 problem
2007-10-24 by bellenger_a