Hi Dave, The 100m modules use +/-15V for the critical circuits and a separate +22V (unregulated) line for the LEDs. The Doepfer supplies are a straight +/-12V and are hence not compatible with the 100m Modules. You would need to modify the supply (and probably use a different transformer) in order for this to work. I reckon you would be better off building a PSU Kit to do this. You can Email me if you want me to point you to some good PSU designs. Cheers, Adam-V --- In Doepfer_a100@yahoogroups.com, David Bulog <d2ba@...> wrote: > > > I have an idea to get specially made a 10hp/te module that will > > have a 6 x 6 pin sockets so you can power some Roland 100m modules > ie it will be cool to use the Roland modules loose without the huge > 191j chassis--- > Has anyone tried anything like this with a 1200ma A100p > > > thanks Dave > > >