AW: [Doepfer_a100] a-190 and a-155 (sync issue)

2008-02-26 by hardware@doepfer.de

> That's a normal problem with sequencers - most of them reset to the
> first step and then, first time a trigger arrives, go to step two. The
> simple workaround is to drop the reset cable and manually advance the
> sequencer to the last step when needed.

If the A-154 is used to control the A-155 the behaviour is different. For
the A-154 a reset signal "prepares" a reset to the step defined by the first
step setting of the A-154. But the advance to this step is triggered by the
rising edge of the next clock signal.

Best wishes
Dieter Doepfer