Yahoo Groups archive

Doepfer

Index last updated: 2026-04-29 00:15 UTC

Message

Re: A-190 and reset proceedure

2008-06-07 by wolfgthiel

Hi David

Was the A-190 working before you did the reset?
Have you checked if all three voltages are ok? -12V/+12V/+5V.
I don't think there is a fuse in the A-190 modul (just had a look at my 
one)and I'm not familiar with the Doepfer power supply. In general you 
could take the fuse out and replace it with a new one of the same 
rating, or if you familiar with a multimeter take the fuse out and 
check continuity of the fuse with an ohm meter.
Good luck.

Wolfgang

--- In Doepfer_a100@yahoogroups.com, David Bulog <d2ba@...> wrote:
>
> I went do a full reset of the A-190 by powerup while holding buttons  
> 1-4 on power up
> When I powered the unit on the lights on the A-190 came on 
momentarily  
> and then no power.
> Has anyone had a similar issue
> 
> BTW -How do I check if fuse is vlown
> 
> thanks David
> 
> 
> 
> 
> [Non-text portions of this message have been removed]
>

Attachments

Move to quarantaine

This moves the raw source file on disk only. The archive index is not changed automatically, so you still need to run a manual refresh afterward.