2008-08-05 by Laurie Biddulph

The stripe is normally used to identify pin 1 and this is the way it should 
be used. However, on systems like Doepfer the only important point is that 
the stripe is orientated to the connector/board the same at both ends i.e. 
bottom-to-bottom (described way) or top-to-top.

Some systems like my Panther, however, use polarised connectors (the headers 
on my modules are boxed and orientated) and it is essential that pin 1 goes 
to the right spot and, theoretically, the strip is not important as long as 
pin 1 is connected to pin 1 and is installed in the right orientation.

So, the technically correct way is that the stripe should identify pin 1 on 
the connector and at both ends. If this is followed by everyone then you 
will not have problems installing power cables as long as you observe the 
orientation markings on the modules that do not use a polarised connector.

Best Regards

(Mr) Laurie Biddulph
Phone: +61 (0)2 4340 0938
Mobile: 0400 257 645

Elby Designs
ABN: 70 022 727 605
http://www.elby-designs.com

This e-mail and any files transmitted with it are confidential and intended 
for the addressee only.
If you are not the addressee you may not copy, forward, disclose or 
otherwise use it, or any part of it, in any form whatsoever. If you have 
received this e-mail in error please notify the sender and ensure that all 
copies of this e-mail and any files transmitted with it are deleted.
Any views or opinions represented in this e-mail are solely those of the 
author and do not necessarily represent those of Elby Designs.
Although this e-mail and its attachments have been scanned for the presence 
of computer viruses, Elby Designs will not be liable for any losses as a 
result of any viruses being passed on.

Please consider the environment before printing this email

----- Original Message ----- 
From: "Monroe Eskew" <monroe.eskew@gmail.com>
To: <Doepfer_a100@yahoogroups.com>
Sent: Wednesday, August 06, 2008 1:16 AM
Subject: [Doepfer_a100] red band orientation


> Is the red band on the power ribbon just a marker to help us?  Is the
> power ribbon functionally symmetrical, so that we can reverse the plug
> orientation on both ends and be alright?
>
> Thanks,
> Monroe
>
> ------------------------------------
>