> Indeed, T&H works correctly but S&H doesn't. Initially I had both > units in S&H mode. I have checked the A-164-1/A-148 combo with A-148 in S&H mode. You are right: this combo does not work. The reason is the AC coupling of the A-148 input in S&H mode in combination with the way how the gate signal is generated by the A-164-1 (connection to +12V via protection resistor). If the A-164-1 is not operated the output is open and the coupling capacitor of the A-148 does not discharge. The T&H does work as in this case the input of the A-148 is DC coupled. I found a simple solution: solder a pull down resistor (about 100k) between GND and the A-148 input. The resistor can be soldered directly to the corresponding terminals of the socket on the bottom side of the A-148 pcb. The 100k resistor connects the A-148 input to GND when the button of the A-164-1 is not operated. Then the AC coupling capacitor of the A-148 is discharged as necessary. I have tried successfully an 100k resistor but I'm sure that any other value in the range 47k ... 220k should do the job. Best wishes Dieter Doepfer