Yahoo Groups archive

Doepfer

Index last updated: 2026-04-29 00:15 UTC

Message

Re: [Doepfer_a100] Sampler CV/Gate Recorder - was: bright new ideas for future Doepfer A100 modules!

2008-10-30 by Florian Anwander

Hi Stu

I have some addon features for this:
> 8/16 (maybe also 24?) bit sampling

> gate (not trigger) for play/record
replace this by:
gate(+switch) for run/stop
gate(+switch) to select between single shot / loop mode
gate(+switch) to switch from gated mode to so called "release-mode" (if 
in single shot, the sample should be played to the end; if in loop mode, 
the loop should be played endlessly until the next start/retrigger is 
given).
trigger(+momentary-switch) for restart
trigger(+momentary-switch) for start
trigger(+momentary-switch) for stop (use case: two samples eliminate 
each other, like hihat/openhat).

> gate to select play or record
This record setting should be an pre-enable setting; the real write 
setting should be done by the start signal.

> cv input for sample rate
> cv input to scan through sample
cv inputs for start point / stop point / perhaps also loop start 
(similar to the editing the Akai S612)

> separate audio outs for monitoring (which i don't need in my patches)
> and playing (to avoid phasing and volume problems associated with
> hearing the original signal and monitor signal together)
> 
> a stereo version would have the advantage of being usable to record cv
> and gate signals for use as a sequencer.
The module should be mono, but there should be the possibility to link 
several modules by the clock and the address bus, so it would become 
stereo or even multi-channel. The write/play selector should stay 
independent on each.


There should be either two (switchable) inputs and outputs: one 
AC-coupled for Audio, one DC-coupled with suppression of negative 
signals for recording CV and/or gate.
Or the module should be produced basically as the identical module but 
in two versions. One ac-coupled for Audio, one for dc-coupled for CV/gate.

The dc-coupled version might have additional three 
trigger-in/momentary-switches for
- count RAM-address one step forward
- count RAM-address one step backward
- write input value to actual step.
This would be similar to the programming of the roland CSQ-600.



Florian