You could send the internal VCO's signal into any oscillator's sync input and the slave should follow the PLL's output signal. That would be probably the simplest way I could think of. On Thu, Dec 4, 2008 at 4:50 PM, Doug <dougc356@yahoo.com> wrote: > Hi folks, I have an A-196 PLL, and I have a simple question. The > internal VCO seems to behave much better given the LPF input than an > external VCO. The LPF signal is typically way too jittery for an > external VCO. The only way I've been able to get an external VCO to > work is to patch the COMP output to a slew then to the external VCO. > Is there something wihtin the circuit between in the LPF output and > the VCO input? Or is the internal VCO special or slewy compared to > typical VCOs? > > Thanks, > Doug > >
Message
Re: [Doepfer_a100] PLL CV Question
2008-12-05 by Don Kim