Re: AW: [Doepfer_a100] A 143-2 Quad ADSR - Receives Gate from system bus?

2009-11-13 by Bakis Sirros

in detail, IIRC:

the A110 and A111, receive from the bus, CV signals and the A140 ADSR receives gate signals. Dieter, correct me if i am wrong.

also the a190: sends cv and gate signals to the busboard.

but, i do not know if the new synth voice module has any normaling to the busboard.


thanks,
Bakis.



Bakis Sirros - Parallel Worlds / Interconnected / Memory Geist

[Doepfer_a100] group owner

www. parallel - worlds - music. com

www. myspace. com/ parallelworldsmusic

www. myspace. com/ interconnectedmusic

www. myspace. com/ memorygeist

www. DiN. org. uk

www. musicamaximamagnetica. com

www. shimarecords. co. uk

www. rubberrecords. gr

Athens - Greece

--- On Fri, 11/13/09, yahoo@doepfer.de <yahoo@doepfer.de> wrote:

From: yahoo@doepfer.de <yahoo@doepfer.de>
Subject: AW: [Doepfer_a100] A 143-2 Quad ADSR - Receives Gate from system bus?
To: Doepfer_a100@yahoogroups.com
Date: Friday, November 13, 2009, 10:48 AM







 



  


    
      
      
      > Hi there,

>

> My Doepfer modular arrived today and it's great. I do have one

> question though.

>

> I know the A190-1 is sending CV notes on the system bus and I had

> expected it to send gate too but my A 143-2 doesn't seem to be

> picking the Gate from the MIDI converter. Is this normal?

> The only way I get the envelopes to work is to patch the Gate

> signal from the A190-1 to the A143-2.

>

> I've looked in the manual to see if it's explicitly described but

> can not find anything, any help is appreciated.

>

> Cheers, Phil



The A-143-2 does not pick up the gate from the bus (that's why you didn't

find it in the manual).

On our A-100 DIY page you find a suggestion for subsequent bus normalling of

modules.



Best wishes

Dieter Doepfer





    
     

    
    


 



  






      