i tried an inverter, but as expected it doesnt work since itll just invert the high voltage to a negative value. What i need to do is change the 190 reset from high on stop and low on start to low on stop and high on start (thats a tounge twister hehe) at this point i've double checked the manual and it would seem this isn't possible via config/midi cc Paul On Sat, Feb 13, 2010 at 1:50 PM, Sandy Brain <sandybrain@gmail.com> wrote: > maybe you could use a separate inverter module? > > On 13 Feb 2010, at 12:03, phono 1337 wrote: > >> seems this runs in reverse, when the midi clock is stopped the synced >> machine starts and vice versa, this is obviously due to the reset jack >> polarity, is it possible to change the reset polarity via the front >> panel or midi cc? I had a look around the manual and it doesn't seem >> to mention it. Anyone have any tips? >> >> Paul >> >> On Fri, Feb 12, 2010 at 11:56 PM, phono 1337 <phono1337@gmail.com> >> wrote: >> > im out of sync sockets and i've already put plenty of splitters >> on the >> > sync outs (msy2/mc202) so im wondering about using the A-190 clock >> > outs as a din sync. >> > >> > Something like >> > >> > a190 clock out to pin 3 on the din connector >> > a190 reset to pin 1 on the din connector >> > a190 ground to pin 2 on the din connector >> > >> > if i set the reset polarity and clock divisor correct im confident >> > this will work, has anyone ever tried this? >> > >> > Paul >> > >> > > > > [Non-text portions of this message have been removed] > > > > ------------------------------------ > > Yahoo! Groups Links > > > >
Message
Re: [Doepfer_a100] Re: would it be possible to use an A-190 clock as a din sync
2010-02-13 by phono 1337
Attachments