> Thanks, Dieter, for your reply. > > So the 177-2 does behave differently from the 177? Because I'm > using the same footswitch as I did with the 177, and I never had > this issue with the 177. Are the capacitors different? I'm not > really equipped to do a modification myself.... The circuits of the A-177 and A-177-2 are totally different. The A-177 used "active" circuits (operational amplifiers), the A-177-2 is a simple passive module with pull-up resistors for the foot switches only (no capacitors). > And isn't the behavior I mentioned in my second message quite > strange? I'll quote it again here: > > "If I have output #1 from the 177-2 double footswitch patched to > the 165 trigger modifier input, and nothing patched from output > #2, only pressing footswitch #1 shows up on the LEDs on the 165. > Footswitch #2 appears to do nothing. So far so good. However, if > I patch from the mini-mult of the 165 to the trigger input of the > S&H 148, then even though only #1 registers on the 165, BOTH > footswitches #1 and #2 pass gate on to the S&H." That's indeed strange. I'll try to copy the behaviour in our demo system. It probably has to do with glitches and bouncing and the different input behaviour of A-165 and A-148 in case of glitches at the input. Best wishes Dieter Doepfer
Message
AW: [Doepfer_a100] Re: 177-2 foot controller issues
2010-04-22 by yahoo@doepfer.de
Attachments
- No local attachments were found for this message.