2010-11-23 by Florian Anwander

Hello

That is something which annoys me too.

I think the A160 should be dropped and a A160-2 should be introduced 
instead which uses a CD4029, which can be switched between counting 
up/down and also with a presettable reset position.

Florian

yahoo@doepfer.de schrieb:
>> Is it possible to modify the A-160 clock divider so that it
>> starts with firing all the gates and goes from there? That it
>> counts from the top instead of from the bottom. Now I have to
>> wait say 32 clocks for it to fire the /32 gate for the first
>> time. It would be easier to run multiple clocked devices in sync
>> if they all started on the downbeat.
>>
>> Martin
> 
> The A-160 uses a standard CMOS counter (CD4024) that cannot be modified.
> Maybe adding inverters do the job you are asking for . In this case all
> (inverted) outputs will turn high on each reset.
> 
> Best wishes
> Dieter Doepfer
> 
> 
> 
> ------------------------------------
> 