Hello That is something which annoys me too. I think the A160 should be dropped and a A160-2 should be introduced instead which uses a CD4029, which can be switched between counting up/down and also with a presettable reset position. Florian yahoo@doepfer.de schrieb: >> Is it possible to modify the A-160 clock divider so that it >> starts with firing all the gates and goes from there? That it >> counts from the top instead of from the bottom. Now I have to >> wait say 32 clocks for it to fire the /32 gate for the first >> time. It would be easier to run multiple clocked devices in sync >> if they all started on the downbeat. >> >> Martin > > The A-160 uses a standard CMOS counter (CD4024) that cannot be modified. > Maybe adding inverters do the job you are asking for . In this case all > (inverted) outputs will turn high on each reset. > > Best wishes > Dieter Doepfer > > > > ------------------------------------ > > Yahoo! Groups Links > > > >