florian, thanks for the question what I would like the most is to just skip a step, if it is 'off' then immediately the next step is taken, so the number of actual steps will be reduced I don't think this option can be made with a reset, because the reset will always give a restart from step one and I really think it is a musical usual feature to skip one or more steps at one moment and switching them on at a later moment, in order to have your sequence varying constantly, in this case you will be able to select some tones of a sequence at a later moment, this is quite different from skipping steps that are -always- on the end of the sequence (i.e. by using the reset)....unless I don't know about the option to use reset for skipping steps in the way I mean it if I remember well some 'vintage' sequencers have the possibility to skip steps and just act like it wasn't there...when you use this feature it gives the real 'TD-Franke' sequence feel.... the second option is something which is already possible, by just directing the trigger or gate of that step to an output that is not connected, at least that is the way I do it, maybe it can be made a bit more elegant....? I noticed a posting on this in the past about a trigger/sequencer: which gives triggers according to a series of 16 switches (a trigger is given whether on or off), if you have such a triggersequencer and use it as a clock for the A154/155 you can elegantly vary the duration of each step in your sequence....this would be a very useful feature too... eric ----- Original Message ----- From: "Florian Anwander" <Florian.Anwander@consol.de> To: <Doepfer_a100@yahoogroups.com> Sent: Wednesday, November 13, 2002 9:28 AM Subject: [Doepfer_a100] A-154 Step skipping > Hi Eric > > > in one of my earlier postings I asked for the step skipping (on/off) > > feature, I still think it > > is one of the most important extra features (well in my case it is...) > What do you mean with step skipping exactly: > > 1.) The address counter should skip one step, reducing the lenght of the > sequence like: 1 2 3 5 6 7 8 = 7 steps > or > > 2.) The address counter should give all steps, but on certain steps there > is no gate signal, like: > CV : 1 2 3 4 5 6 7 8 > Gate: x x x . x x . x > > > To my opinion the latter makes sense, but the first proposal is quite > sensless. Instead of you could use a reset function. > > For the second proposal I would prefer a additional gate sequencer with > three position switches: > up=bound (the gateout is logical YES for the whole step length) > middle=normal (Gate pulse). > down=no gate for this step > > > Florian > -- > Florian Anwander |ConSol* HP-Support > Tel. +49.89.45841-133 |Consulting&Solutions Software GmbH > Fax +49.89.45841-139 |Franziskanerstr. 38, D-81669 München > email: florian.anwander@consol.de |http://www.consol.de > > To unsubscribe from this group, send an email to: > doepfer_a100-unsubscribe@yahoogroups.com > > > > Your use of Yahoo! Groups is subject to http://docs.yahoo.com/info/terms/ > >
Message
Re: [Doepfer_a100] A-154 Step skipping
2002-11-13 by Quantum Productions
Attachments
- No local attachments were found for this message.