Yahoo Groups archive

Doepfer

Index last updated: 2026-04-29 00:15 UTC

Message

Re: [Doepfer_a100] trouble with VC patching to second G6 frame

2015-07-02 by Nicholas Keller

If I understand mains and the PSU2 correctly, the chassis is grounded to the ground prong on the power plug, while the electronics is "grounded" to the neutral prong. So each case would work separately, but not when combined.






On Thursday, July 2, 2015, acgenerator@att.net [Doepfer_a100] <Doepfer_a100@yahoogroups.com> wrote:

I finally got it fixed.

Here was the issue: apparently even though both both sets of boards were hooked up correctly to grounds used independently. They mismatched on the order of using the 4 ground connections.

One had Top-unsed-Chassis-Bottom; the other unused-Top-Chassis-Bottom across the ground posts.

thanks for those that helped getting me on the right track!

Attachments

Move to quarantaine

This moves the raw source file on disk only. The archive index is not changed automatically, so you still need to run a manual refresh afterward.