Yahoo Groups archive

Doepfer

Index last updated: 2026-04-29 00:15 UTC

Message

Re: a185 question

2002-12-07 by ps_minor <pscottm@hotmail.com>

wow, excellent result joe!   thanks for taking the time to try a patch 
w this arrangement, hopefully others will benefit from your test 
as i have.   
coincidentally, i just ordered a 185 earlier today.  to be honest,  i 
really didn't think it would work w a mult..glad to know know now 
that it will.
cheers,
ps minor





--- In Doepfer_a100@yahoogroups.com, "Joe Buechler 
<buechlerjoe@t...>" <buechlerjoe@t...> wrote:
> Hi ps
> 
> Welcome to the group.
> 
> I tried your proposed setup - A185 bus access module patched 
to an 
> A180 multiples, and from there to three VCOs (de-normaled 
from the 
> system bus). It stayed in tune with a reference pitch. Without 
the 
> A185 it didn't work.
> 
> I also tried it with an A170 slew limiter patched in before the 
A185. 
> Same result, no pitch problems with the A185 driving the VCOs 
via the 
> multiples.
> 
> It looks like your plan will work.
> 
> Joe
> 
> --- In Doepfer_a100@yahoogroups.com, "ps_minor" 
<pscottm@h...> wrote:
> > hello all,
> > i'm a new member of the list and i have a question re the 
a185 
> > bus access module.  
> > i saw in the archives that this is the module necessary to 
prevent 
> > tuning probs when using a slew limiter for portamento.  (i 
just 
> > got an a171 and i'm experiencing this problem)
> > 
> > i have 2 6U cases, mostly doepfer, one w an a190.  thing is, i 
> > don't use the bus because my oscillators and most 
frequently 
> > used filter are NONdoepfer (they're ASys).  is the a185 
> > substantial enough to keep voltages constant even when 
bus is 
> > not part of the equation?  
> > 
> > ASys has a solution but i prefer the a185 to the ASys cv buffer 
> > mainly because the doepfer is smaller and 1/3 the price.  on 
the 
> > other hand the a185 has only 2 buffered cv outputs vs ASys's 
7.
> > 
> > question:  can the a185 hold up to having its output plugged 
into 
> > a mult?   will it sense the voltage draw and keep more than 2 
> > oscillators in tune?  (i commonly use 3, sometimes 4)
> > 
> > any insight is appreciated.
> > 
> > -ps minor

Attachments

Move to quarantaine