> Hello Dieter, > > > I have an issue with the A156. > > Besides the small notes on your website about tuning the A156 is > there a more specific thing to measure? > Between the steps of 0.0833333 V there is a small window of quantizing. > When the voltage goes up and down there it switches differently. > I ask this because I used the P4 with a reference voltage of 1.00 > , 2.00 , 3.00 and 4,00V. > Afterwards I used P1 and P2 to adjust but then I lost it a bit. > Within voltage steps everything seems ok but now I"ll have to put > the 0,083333 steps one by one and see if the output follows right? > Where are the points where the quantizer switches? > What is the factorysetting for that, when going voltage up and when down. > > Hope that I made a clear explaination. > > Best regards. > > Jacco Ville > The Netherlands I'd recommend to adjust the CV outputs with a wide spread (e.g. 0/5V). The difference has to be as close as possible to 5.00V (e.g. +0.016 and +5.016V or -0.03 and +4.97V), the absolute values are not important. The CV values in between are defined by the precision (linearity) of the used DAC and cannot be adjusted. Best wishes Dieter Doepfer
Message
AW: [Doepfer_a100] Tuning references for A156 quantizer
2016-08-18 by yahoo@doepfer.de
Attachments
- No local attachments were found for this message.