Hello, please make sure that the output level of the Gate/Clock/Reset/Start/Stop outputs is set to +12V (not +5V). And make sure that the frequency of the A-147-2 is not too low. The frequency of the A-147-2 should be not much less than the clock signal coming from the Dark Time. Otherwise the period of the A-147-2 is to low to generate a noticeable signal before the next reset appears. Best wishes Dieter Doepfer > -----Ursprüngliche Nachricht----- > Von: Doepfer_a100@yahoogroups.com [mailto:Doepfer_a100@yahoogroups.com] > Gesendet: Dienstag, 25. Dezember 2018 19:52 > An: Doepfer_a100@yahoogroups.com > Betreff: [Doepfer_a100] A147-2 VCDLFO question > > > Hello and happy christmas to everyone, > > I am using an external clock e.g from dark time to sync/reset the A147-2, > as soon as I am increasing the frequency knob of the lfo, the > outputs are in perfect > sync with the external clock. As soon as I am decreasing the > frequency knob I have no > output signal from the lfo, the leds are not blinking. Is it a > normal behaviour? > > > Best regards, > Miltos
Message
AW: [Doepfer_a100] A147-2 VCDLFO question
2019-01-02 by yahoo@doepfer.de
Attachments