A-152 question

2019-04-07 by exakoustidismiltiadis@hotmail.com

Hello again!


I am a happy owner of this fantastic and versatile module!

But I have some questions, maybe I have them due to my poor English.


I read in the manual, page 5

Only control voltages can be processed by the T&H unit due to the holding capacitors of the T&H circuits. The T&H section is not suitable for audio signals.


First of all I suppose that I can eject a slow LFO. If I am right, until how many Hz T&H section

can process?


Secondly, again in the manual, page 6.

JP8 top, JP7 away from the common T&H (factory setting) .

In this case the common input of the T&H unit 2b is connected to the common socket of the multiplexer unit 1b provided that no plug is inserted into the common input of the T&H unit 2b.


Provided that only control voltages can be processed by the T&H unit, if I inject an audio signal in Common

Switch input it will be transferred in the common T&H Input because of the normalization. This is illogical to

me. Maybe I misunderstand something, I am asking kindly of your help!


Best regards,

Miltos