hello florian, that's exactly what i do when i control many envelopes from the same gate source. bakis. --- Florian Anwander <Florian.Anwander@consol.de> wrote: > Hi Bakis > > > you mean that some analogues need a higher gate > > voltage for their envelopes to be triggered, > right? > It is not the voltage, it is the different input > impedance of several > destinations that are fed from the same voltage > source. The different > inputs have to be decoupled (right word?) from each > other. > > An example is: I use the sequencer of the SH-101. > SH-101 Gate Out -> A140 only: works fine > > SH-101 Gate Out -> Formant-Env only: works fine > > SH-101 Gate Out -> A140 + Formant-Env: the A140 does > not tr�gger and the > Formant does not react always. > > > The solution is: > SH-101 Gate Out -->A185 -> Formant-Env > \->A185 -> A140 > > > (I do not use the A185 in the Formant, but have a > diy buffer circuit in > the Formant) > > Florian > > > > --- Florian Anwander <Florian.Anwander@consol.de> > > wrote: > >>Basically the connection between each gear > requires > >>to obey certain > >>circumstances, and I had to modify the most pieces > >>to fit easy together. > >>Most times a buffering of Gate-Voltages is > required. > > > ===== Bakis Siros Parallel Worlds / Polariton Athens-Greece [Doepfer_a100] group owner http://www.shimarecords.co.uk http://www.ward12.com _______________________________ Do you Yahoo!? Declare Yourself - Register online to vote today! http://vote.yahoo.com