> -----Ursprüngliche Nachricht----- > Von: Doepfer_a100@yahoogroups.com > [mailto:Doepfer_a100@yahoogroups.com]Im Auftrag von Florian Anwander > Gesendet: Donnerstag, 16. Juni 2005 09:45 > An: Doepfer_a100@yahoogroups.com > Betreff: Re: [Doepfer_a100] MS-404 CV/Gate outputs > > > Hi Steve > > > The question is, will the the 404 be able to provide a stable > CV for up to 3 > > modules (2 VCO & 1 VCF) without getting overloaded? > To my experience: yes. > > Florian I'd recommend the usage of an A-185 bus access module as the MS-404 has a serial 1k protection resistor and inductor (because of EMC compliance / CE sign) in it's CV output. By loading the output with 3 module (~ 100k each or ~33k altogether) there might occur a small voltage loss in the CV signal. The A-185 has a high impedance input and includes a voltage buffer for CV and consequently will avoid a voltage loss. P.S. The MS-404 service manual is available on our web site (-> MANUALS -> user's guides of older devices -> MS-404 user's guide -> MS-404 service manual). Best wishes Dieter Doepfer
Message
AW: [Doepfer_a100] MS-404 CV/Gate outputs
2005-06-16 by Dieter Doepfer
Attachments
- No local attachments were found for this message.