Dieter, Many thanks for the info - I was wondering what I could buy to fill a few more rack spaces ;-) Steve > > Hi Steve > > > > > The question is, will the the 404 be able to provide a stable > > CV for up to 3 > > > modules (2 VCO & 1 VCF) without getting overloaded? > > To my experience: yes. > > > > Florian > > I'd recommend the usage of an A-185 bus access module as the MS-404 has a > serial 1k protection resistor and inductor (because of EMC compliance / CE > sign) in it's CV output. By loading the output with 3 module (~ 100k each or > ~33k altogether) there might occur a small voltage loss in the CV signal. > The A-185 has a high impedance input and includes a voltage buffer for CV > and consequently will avoid a voltage loss. > > P.S. The MS-404 service manual is available on our web site (-> MANUALS -> > user's guides of older devices -> MS-404 user's guide -> MS-404 service > manual). > > Best wishes > Dieter Doepfer