From my understanding this can realized with an A-149-1, VCA (e.g. A-132)
and mixer (e.g. A-138a). The clock is the A-149-1 clock, lower CV goes to
one A-138a input (kind of mixer offset), the A-149-1 output is processes by
a VCA with VCA CV as upper CV, the VCA output goes to another mixer input.
The mixer output is the Tendency mask generator output. The A-149-1 could
also be replaced by an random module A-118 and a S&H A-148. In this case the
clock goes to the A-148 clock input.

I don't think that it justifies a new module even though it would be no
problem for us.

Best wishes
Dieter Doepfer

> -----Ursprüngliche Nachricht-----
> Von: Doepfer_a100@yahoogroups.com [mailto:Doepfer_a100@yahoogroups.com]
> Gesendet: Mittwoch, 21. September 2005 04:02
> An: Doepfer_a100@yahoogroups.com
> Betreff: [Doepfer_a100] Poll results for Doepfer_a100
>
> The following Doepfer_a100 poll is now closed.  Here are the
> final results:
>
>
> POLL QUESTION: Would you like Doepfer to manufacture a Tendency Mask
> Generator module? (the Tendency mask generator at Sonology
> is a device which you feed an upper limit and a lower limit
> as cv inputs [in a doepfer system it could be
> an extension of the a172 max/min]. There's also a clock
> which can either be internal or an external pulse. The
> device gives out random values between the upper and lower
> limits at the clock rate.)
>
>
> CHOICES AND RESULTS
> - yes!, 17 votes, 54.84%
> - maybe, 7 votes, 22.58%
> - no., 7 votes, 22.58%
>
>
>
> For more information about this group, please visit
> http://groups.yahoo.com/group/Doepfer_a100
>
> For help with Yahoo! Groups, please visit
> http://help.yahoo.com/help/us/groups/
>
>
>
>
>
>
>
>
> Yahoo! Groups Links
>
>
>
>
>
>
>

Attachments

Move to quarantaine

This moves the raw source file on disk only. The archive index is not changed automatically, so you still need to run a manual refresh afterward.