Thanks Dieter, i stock up on different types of fuses and will test those during next few weeks or so (also the ones you rcommended - 0.63A). thanks for a detailed description. cheers all and happy holiday season tomek On 19/12/05, Dieter Doepfer <hardware@doepfer.de> wrote: > > The fuse values are recommended by the manufacturer of the transformer and > we took them over without changes. We test all A-100 systems and frames > that > are manufactured in our company with the full load (i.e. 650mA for the old > version of the power supply and 1200 mA for the PSU2). For empty frames we > use dummy loads (high power resistors) to simulate the load. So far we > never > discovered a blown fuse during the final test (of course expect if there > was > a fault) with the specified values. > As we have no "real" 115V mains voltage available in Germany we use a > 230->115V transformer for testing the 115V systems and frames. Maybe the > "real" 115V mains behaves a bit different, as the 230->115V transformer > causes an additional delay until the full mains voltage is available. > > In any case one has to pay attention of the blow type. In any case the > slow > version (time lag) is necessary. Fuses with medium or fast response may > blow > during power on! If you are sure that you use a time lag/slow blow fuse > with > the right value (500mA for 115V and PSU2) you may increase the value to > the > next step (630mA is the next common value here in Germany). This is OK as > even a 630mA fuse will blow in case of e.g. a short circuit. > > In any case I have to warn against the usage of metal foils or other > conductive materials to short the fuse. It is OK to use a fuse with the > next > higher value. But never short the fuse ! This is extremely dangerous and > may > cause fire or other damages. > > Best wishes > Dieter Doepfer > > P.S. We have about 15 PSU1 left. When they are used up only the PSU2 will > be > manufactured. > > > > > -----Ursprüngliche Nachricht----- > > Von: Doepfer_a100@yahoogroups.com > > [mailto:Doepfer_a100@yahoogroups.com]Im Auftrag von tkrakowiak > > Gesendet: Samstag, 17. Dezember 2005 22:03 > > An: Doepfer_a100@yahoogroups.com > > Betreff: Re: [Doepfer_a100] Re: fuse issue (Correction) > > > > > > hello, > > > > don't think it's shorting anywhere inside the suitcase (it's got > > composite-plastic walls and aluminum railings which shouldn't affect > even > > when touched), but i'll check anyway. it seems to happen only when i'm > > taking it somewhere (that's why i asked about moisture buildup) , when > it > > happened yesterday (2 fuses, 1 after another:) i only saw a blink > > of led on > > a119. > > soooo.... could i _safely_ try a different variety of fuses?? > > somewhat desperately looking for answers ( Dieter ?). > > have a nice weekend all. > > cheers > > t > > > > > > > > > > > I'm not sure if this is the problem you are having, but some Doepfer > > > modules have PC boards *very* close to the edge of the module and it's > > > possible that the power traces are shorting out against your case. > > > This happened to me when I tried to install a certain Doepfer module > > > (either the Quad ADSR or Triple Bandpass, I can't remember which) in > an > > > Asys RS15 euro-rack.... the traces on the lowest PC board touched > > > against the case and shorted out the whole system. The worst part is > > > that it fried 2 of my modules and I had to pay $180 to fix them. > > > Now I don't know if the Doepfer cases are the exact same dimensions as > > > the RS15, but you might want to check and see if any of your modules' > > > PC boards can touch the case under rigorous patching conditions. > > > Usually when a fuse keeps getting blown, there is an intermittent > short > > > in the electrical system... or you are getting really bad power spikes > > > from your AC line. I assume you are using some sort of surge > protector? > > > > > > [Non-text portions of this message have been removed] > > > > > > > > > > > > Yahoo! Groups Links > > > > > > > > > > > > > > > > > > Yahoo! Groups Links > > > > > > > [Non-text portions of this message have been removed]
Message
Re: [Doepfer_a100] Re: fuse issue (Correction)
2005-12-19 by tkrakowiak
Attachments
- No local attachments were found for this message.