AW: [Doepfer_a100] A113 current

2006-02-06 by Dieter Doepfer

TD,

yes. As the current @+5V is taken from the +12V rail you have to add the +5V
current. For the A-113 the total current is 150mA provided that the low-cost
5V adapeter (A-100AD5) is used. Only of a separate +5V power supply is in
use (A-100NT5) the current of the A-113 taken from the A-100 12V supply
(standard or PSUII) is only 50mA.

Best wishes
Dieter Doepfer

> Wanting to measure the current in my system, I am curious how do I value
the A113?
> Does 50MA + 100MA@+5V (using the +5V power supply on the board) =150MA?
>
> Thanks.
> TD