Hello Dieter and also to the rest of the folks on here. Thanks for the feedback. I checked page 10 in the manual, and since I am not sending midi messages via an external controller, I think I might still be having problems somewhere in the programming of the 190 itself. I have tried every possible division (programming step at a time in the FLO Freq/Clock menu) by hand, and everything still seems to send a non- quartered (triplets?) hardware pulse to the filters that I am trying to control. Would it be easier for me to just add a clock divider module between the 190 and 155... and then send different divisions to different dedicated filters and to the sequncer? Sixtoo "You have to set the clock dividing factor to 6, 12 or 24 to get 1/16, 1/8 or 1/4 hardware clock pulses from the A-190. Please look at the A-190 manual to page 10. I know that the A-190 operation is not the best (I would never design the A-190 again as it is but it was develeoped by an employee in cooperation with an external consultant - in the meantime I don't think much of external consultants but listen to the suggestions of this group ....)" Best wishes Dieter Doepfer [Non-text portions of this message have been removed]
Message
Re: [Doepfer_a100] Digest Number 1401
2006-02-07 by Sixtoo.1200Hobos
Attachments
- No local attachments were found for this message.