Re: [ElektorFormant] Re: Panick, Please Help 12v in VCO

2005-03-09 by Dirk Vanden Berghe

Hi Guys,
In Belgium we need a TVA-number to buy at Farnell. I buy my components in Germany. www.conrad.de
prices are more then acceptable. 
There's a www.conrad.com too, for the UK, and in France, and the netherlands. However, I found out that Germany is the cheapest and if you group orders... it's worth paying the extra for transport.
Don't know if getting them to Scotland is possible.
bye

laurence2715 <laurence.cope@...> wrote:

Kris.

These are readily available, farnell have loads of them @ 8p each. 

Sorry to kick you in the shins with this little note, I could have 
also got them as samples from the manufacturer.

If there is any thing you want and you hav'nt got an account, let me 
know and an arangement could be set up.


Rgds

Laurence



--- In ElektorFormant@yahoogroups.com, "Kris Bishop" 
<bishopkris40@h...> wrote:
> 
> Hi,
> Sorry was just being stupid, sorted it out after posting question. 
> That's all my parts ordered. To anyone trying to buy BC557C's their 
> is a guy in China selling some but costing me \ufffd113 to get 32 of 
them 
> shipped to scotland.
> 
> Kris
> 
> --- In ElektorFormant@yahoogroups.com, Dirk Vanden Berghe 
> <dirkyformant@y...> wrote:
> > Hi Kris,
> > All boards get +-15V and if other voltages are needed they are 
> changed on the board with 78- and 79-ers. Not the cheapest solution 
> it is....
> > I'm not doing this and made one major power supply with all the 
> voltages I might need. I got hold of two industrial 24V supplies 
and 
> derive -24V, -15V, -12V, +5V, +9V, +12V, +15V and +24V from it. 
Even 
> have several modulars running on the same supply. 
> > Dirk
> > 
> > Kris Bishop <bishopkris40@h...> wrote:
> > 
> > Hi,
> > 
> > I'm currently pulling in all the components I needed for my 
Formant
> > MSS2000 to be built. Doing Ok so far.
> > 
> > Where does the 12v and 5v supply for the vco come from, Does IC4, 
> and
> > IC7 produce this? As I'm controlling my synth via a digital 
> interface
> > in the shape of a midijack I need only provid a board with a CV 
and
> > Gate out which I planned to create with a couple of voltage 
> followers
> > and from there input these into the BUS system and use 3.5mm 
> sockets
> > on the bus access module to provide CV and gate outputs.
> > 
> > My real problem is will the VCO's run with just the normal +15 
> and -15
> > v  inputs as specified and create the relative voltages or do you 
> need
> > more supply voltages. (I think it looks as if they are created on 
> the
> > VCO boards)
> > 
> > I need to know as soon as possible as if I need to I will have to
> > create an interface board.
> > 
> > Cheers
> > Kris Bishop
> > 
> > 
> > 
> > 
> > 
> > 
> > 
> > 
> > Yahoo! Groups SponsorADVERTISEMENT
> > 
> > 
> > ---------------------------------
> > Yahoo! Groups Links
> > 
> >    To visit your group on the web, go to:
> > http://groups.yahoo.com/group/ElektorFormant/
> >   
> >    To unsubscribe from this group, send an email to:
> > ElektorFormant-unsubscribe@yahoogroups.com
> >   
> >    Your use of Yahoo! Groups is subject to the Yahoo! Terms of 
> Service. 
> > 
> > 
> >             
> > ---------------------------------
> > Celebrate Yahoo!'s 10th Birthday! 
> >  Yahoo! Netrospective: 100 Moments of the Web




Yahoo! Groups SponsorADVERTISEMENT


---------------------------------
Yahoo! Groups Links

   To visit your group on the web, go to:
http://groups.yahoo.com/group/ElektorFormant/
  
   To unsubscribe from this group, send an email to: