Re: [Fairlight-CMI] Mitsubishi 2896-63 8 " drive jumper settings

2005-10-24 by Laurent Lemaire

Hi James,

Here is the list of jumpers to be closed on the 2896-63 drive to be used in a CMI 3:

JFC, PS, SE, DC, M2, S2, I, R, IT, MS, M0, RFA, HR, A, HUN, WP, DS, 2S, RM

All other options block to be left open...

Hope it helps.

Laurent.


On 24 oct. 05, at 21:44, James Thomson wrote:

Hi Guys,


Does anyone have the jumper settings for the Mitsubishi 2896-63 8" floppy
drive ? This drive is in the CMI series 3 instrument as well as a few CMI 2X
systems. I want to use it in a CMI 2X but there are many jumpers on the PCB
board !
Is this information in the series 3 service manual ? Can anyone make me a
copy of the series 3 service manual ? Many thanks !

Regards,


James Thomson