Yahoo Groups archive

Homebrew PCBs

Index last updated: 2026-04-28 23:05 UTC

Message

Re: [Homebrew_PCBs] Re: Ferric Chloride - muck at bottom of tank question

2006-05-07 by Leon Heller

----- Original Message ----- 
From: "Stefan Trethan" <stefan_trethan@...>
To: <Homebrew_PCBs@yahoogroups.com>
Sent: Sunday, May 07, 2006 5:26 PM
Subject: Re: [Homebrew_PCBs] Re: Ferric Chloride - muck at bottom of tank 
question


> On Sun, 07 May 2006 18:07:13 +0200, fenrir_co <fenrir@...>
> wrote:
>
>> Be careful with the H2O2, while FeCL3 doesn't cause burns quickly,
>>
>> peroxide at that strength will. Always mix outdoors and add slowly,
>>
>> this creates large amounts of foaming and heat.
>>
>
>
> Sounds like a rather wild procedure ;-)
> Any gas that is released when adding H2O2 is probably something you would
> rather wish to keep in the etchant (like oxygen), so if you get bubbles
> that is not always a good thing. At least that's how it is with CuCl,
> there you do not want to add so much to cause bubbles to form and heating,
> because it is only a waste of chemicals.
>
> I'm not quite sure if i had the choice between nursing FeCl on to last
> forever, and starting with clean, fresh CuCl with no FeCl at all, if i
> would choose to use any FeCl. I don't quite see the advantage, i mean, is
> it actually regenerated or is this only CuCl with some used up FeCl
> swimming around in it and making things dirty and blocking the view?

The ferric chloride gets regenerated, of course. The solution is rather 
dark, though.

Leon


---
[This E-mail has been scanned for viruses but it is your responsibility 
to maintain up to date anti virus software on the device that you are
currently using to read this email. ]