Yahoo Groups archive

QTR-Quadtone RIP

Index last updated: 2026-04-28 23:12 UTC

Message

Re: [QuadtoneRIP] Re: Invalid Linearize curve

2005-10-20 by Rainer Taube

lours51 wrote:

>
> Rainer,
>
> I don't draw the Eye1 but place it patch after patch, is it more
> accurate , I don't know but I didn't find the way to draw it on the
> patches.
>
> Michel
>
Michel,

Looking again in your values, i suppose something must be wrong because 
the nearly no diffenrence in the values between 60 and 100% (the range 
is from 17,68 to 15,29). That means nearly black for all patches from 60 
to 100%, to much ink. Do you print with 2880 dpi. I found that 2880 dpi 
brings down to much ink.

For example here the values from the KayentaSepia i made yesterday by 
drawing the EyeOne over the stepwedge. You can see that the values range 
from 43,82 to 19,55.

File: C:\Dokumente und Einstellungen\Rainer\Eigene 
Dateien\Messungen\RT1440UCKayentaSepia-out.txt
Step    Dens    Lab    A    B   
0.00    0.045    96.04    2.09    -9.23    b                             
|       a                  L  +
5.00    0.094    91.90    2.54    -7.29    b                             
|         a              L    +
10.00    0.157    86.82    2.87    -4.64    -          
b                  |          a          L       +
15.00    0.226    81.51    3.08    -2.19    -                    
b        |           a     L           +
20.00    0.300    76.13    3.35    -0.07    -                            
b|            a L              +
25.00    0.370    71.31    3.24    1.92    -                             
|      b    a                 +
30.00    0.445    66.43    3.22    3.14    -                             
|        L  b                 +
35.00    0.520    61.83    2.93    4.62    -                             
|      L   a      b           +
40.00    0.590    57.75    2.62    5.84    -                             
|   L     a            b      +
45.00    0.658    54.02    2.45    6.44    -                             
| L      a               b    +
50.00    0.722    50.66    2.13    7.37    -                             
L       a                    b+
55.00    0.781    47.69    1.80    8.01    -                           L 
|      a                      b
60.00    0.863    43.82    1.64    7.69    -                         L   
|     a                       b
65.00    0.971    39.05    1.57    6.75    -                      L      
|     a                    b  +
70.00    1.076    34.79    1.61    5.72    -                   L         
|     a               b       +
75.00    1.200    30.18    1.60    4.52    -                 L           
|     a           b           +
80.00    1.305    26.59    1.50    3.37    -              L              
|     a      b                +
85.00    1.397    23.71    1.35    2.54    -             L               
|    a    b                   +
90.00    1.461    21.79    1.11    1.98    -            L                
|   a  b                      +
95.00    1.507    20.48    0.94    1.62    -           L                 
|  a  b                       +
100.00    1.541    19.55    0.80    1.82    -          
L                  |  a   b                      +

Created ICC file C:\Dokumente und Einstellungen\Rainer\Eigene 
Dateien\Messungen\RT1440UCKayentaSepia.icc

Why did you scan your printout and do not measure directly the 100% 
value of each ink with the EyeOne. The scanning brings up one more 
possible error source.

Regards

Rainer

Attachments

Move to quarantaine

This moves the raw source file on disk only. The archive index is not changed automatically, so you still need to run a manual refresh afterward.