Yahoo Groups archive

QTR-Quadtone RIP

Index last updated: 2026-04-28 23:12 UTC

Message

RE: [QuadtoneRIP] 2200 Printing Problem

2005-11-07 by John Tunley

Tom,

I have often experienced the same problem with an Epson 2100 when using HPR
and QTR. Epson papers are less of a problem and, as you say, with the Epson
driver there is no problem. 

It seems to be caused by a slight slippage in the paper feed, possibly due
to some coating transfer from paper to drive rollers. It usually occurs
after a few prints have been successfully completed. Feeding from the rear
feed slot is always recommended for thicker papers. I have generally
overcome the problem when feeding the lighter HPR paper (188g/m^2) from the
top by encouraging the paper feed by hand with a gentle initial push. 

Regards,   John T


-----Original Message-----
From: QuadtoneRIP@yahoogroups.com [mailto:QuadtoneRIP@yahoogroups.com] On
Behalf Of Tom Husband
Sent: 06 November 2005 23:24
To: QuadtoneRIP@yahoogroups.com
Subject: [QuadtoneRIP] 2200 Printing Problem

QTR 2.3.10
Quad2200-UT7 ink
XP

I'm trying to run an ink density calibration but when I print the
paper will just travel all the way through the printer without
printing or it will just start to go through and stop.  The first
calibration I ran printed just fine but now the second print hangs or
goes all the way through.  Sometimes if I cancel the print job and
reboot it will work but most times the same thing happens.  I just
cancelled the job and tried to print an image and it printed just fine
so I tried to print the calbration print again and it hangs.  However
sometimes images have the problem too.  My 1280 used to do it too.  I
can't determine a pattern to the problem.  When I print with Qimage
through the Epson driver it always prints correctly.

Has this happend to anybody?

Thanks,

Tom


-- 
No virus found in this outgoing message.
Checked by AVG Free Edition.
Version: 7.1.362 / Virus Database: 267.12.8/162 - Release Date: 05/11/2005

Attachments

Move to quarantaine

This moves the raw source file on disk only. The archive index is not changed automatically, so you still need to run a manual refresh afterward.