Roy Harrington wrote:
> Hi Ernst,
>
> The input files to QTR-Linearize-Data and QTR-Create-ICC are very
> flexible.
> It'll understand most any text file data organized in columns. The
> columns
> should be separated by spaces or tabs.
>
> The important columns are:
> 1) Gray -- 0 to 100, basically the same as K in Photoshop.
> or RGB -- 255 to 0, can be used as a substitute for Gray.
> if missing it assumes N evenly spaced samples
> 2) L, LAB, LAB_L -- > 0 to < 100, the L measurements
> 3) A, LAB_A -- A measurements (optional, A=0 if not there)
> 4) B, LAB_B -- B measurements (optional, B=0 if not there)
> or D, Density -- 0 to 4, density instead of L values, but no color
> then.
>
> duplicate samples are allowed -- they are averaged.
>
> a trivial example:
>
> Gray L A B
> 0 96.1 1 2
> 50 56.3 3 5
> 100 15.8 -2 -1
>
> -----------------
> Trying to copy the MT output is way more complicated than needed.
>
> Roy
>
>
> On Tuesday, August 1, 2006, at 12:44 PM, Ernst Dinkla wrote:
>
>> Could someone send me a file that is created with the Eye One
>> and Measure Tool so I can edit files made with the SpectroCam
>> that they suit QTR-Linearize-Data and QTR-Create-ICC ?
>> If possible the 4 versions 21, 51, random, etc.
>>
>> Ernst
>> --
>> --
>> Ernst Dinkla
>>
>>
>> www.pigment-print.com
>> ( unvollendet )
>>
>>
> -
> Roy Harrington
> roy@...
> Black & White Photo Gallery
> http://www.harrington.com
I would like to thank everyone for helping me in this case. I
will report back what the easiest solution is with the
SpectroCam. There will not be many around with that
spectrometer but it still does a good job here.
Ernst
--
--
Ernst Dinkla
www.pigment-print.com
( unvollendet )Message
Re: [QuadtoneRIP] Eye-One / Measure Tool - file asked
2006-08-02 by Ernst Dinkla
Attachments
- No local attachments were found for this message.