Yahoo Groups archive

QTR-Quadtone RIP

Index last updated: 2026-04-28 23:12 UTC

Message

Re: banding UT7 - Solved

2008-07-07 by stephane_bosman

Wht I had was more like posterization in smooth light gradients.

The problsm was that I did the linearization with the 51 steps target 
instead of 21.

I redid my calibration andprofiling and now everything is fine.

--- In QuadtoneRIP@yahoogroups.com, "stephane_bosman" 
<stephane_bosman@...> wrote:
>
> I just noticed exactly the same problem.
> 
> Inks: UT (not UT7
> Driver : QTR 2.6.1
> OS: Mac OS 10.5.4
> 
> Could it be something that appeared after QTR 2.3?
> 
> Regards
> 
> --- In QuadtoneRIP@yahoogroups.com, "studiofahrenheit"
> <studiofahrenheit@> wrote:
> >
> > hi
> > 
> > I have problem with my printer (epson stylus pro 9600) of very 
large
> > orizontal banding betwen density 60 up to 90, with any kind of 
paper
> > (galerie gold silk, harman gloss fb al, hahnemuhle baryta).
> > we use ink Ut7 with rechargeble cardriges, we perform several hard
> > cleaning and head allignement.
> > also we linearize all the paper with Print Fix Pro and Quad Tone 
Rip.
> > the ink set is been bought on August 2007.
> > 
> > thank you
> > 
> > gianni romano
> >
>

Attachments

Move to quarantaine