Actually on reflection I don't think you need to sort them. I do that because I like to view a graph of the results before I give it to QTR-Create-ICC. I presume your out of order values are in the dark blacks? If so then your problem is simply that you are putting down too much ink. Mike 2008/10/10 Michael King <drmrking@...>: > So measure tool reports the readings in the "random" order of the > print out and you need to sort the results before you give them to > QTR-Create-ICC. I do this in Excel. Don't sort by the actual Lab > reading, sort by the expected value. That way if you really do have > some out of order readings, QTR-Create-ICC will warn you. > > Mike > > 2008/10/10 slcphoto73 <slchapin@...>: >> I have just printed Step-51-random.tif, run MeasureTool and measured >> the three strips as strip-without-gaps. When I put the saved .txt file >> into QTR-Create-ICC it tells me the Lab values are not in order and it >> can't make the profile. And yes, I observe some Lab values out of >> order in the "out" text file. >> >> I have repeated the measurement multiple times. I tried measuring as >> patches but I couldn't properly center the spectrophotometer on the >> patches, so it had the same problem only worse. >> >> What might be wrong and how do I correct it? >> >> I am running QTR v. 2.6.1.0, with CreateICC dated 9/18/2007. >> >> Thank you, >> >> - susan >> >> >
Message
Re: [QuadtoneRIP] Help using QTR-Create-ICC.exe
2008-10-10 by Michael King
Attachments
- No local attachments were found for this message.