Re: [QuadtoneRIP] Re: Need help with i1 Profiler

2011-08-28 by Roy Harrington

Sean,

I've used it a lot so I went back and looked at the sequence.
When you are on the page that says "Mode: Patch" you pull that down to
select "Strip without gaps".  The second pull down that said Manual goes away.
The Start button also goes gray because you use the button on the device
to start the scan.   Place the device on the white spot under "Beg" on
the paper.
Push the button and wait for a low beep sound (about a second) then drag
the device steadily across the patches to the white at other end. Stop and
then let up button on device.  If you hear 3 beeps thats an error you can try
again. Otherwise, "Close" and "Save As" on next dialog.

Roy

On Sat, Aug 27, 2011 at 3:35 PM, spsguru <spsguru@...> wrote:
> OK- now I am stumped.
> The Measure Tool grays out the Start button when I choose anything other than manual - so I cannot scan strip without gaps
>
> And the manual tool does not begin on white but right on the patch.
>
> I must be missing something obvious but dont know what it is - cannot you not scan Strips without a dongle?
>
> Sean
>
> --- In QuadtoneRIP@yahoogroups.com, Michael King <drmrking@...> wrote:
>>
>> yep you got it - it will tell you if it reads the line correct.
>> if not try starting with a bit more white and ending with a bit more white.
>>
>> you need to press the button on the i1 device to start each line.
>>
>> good luck
>>
>> On 27 August 2011 01:20, spsguru <spsguru@...> wrote:
>>
>> > **
>> >
>> >
>> > Mike - this is just the kind of insight I was hoping for...can never seem
>> > to find this stuff in a manual.
>> >
>> > No - I was scanning using Patches not strip
>> >
>> > So - Strip without Gaps - start on white end on white - for each line -
>> > correct?
>> >
>> >
>> > thank you
>> > Sean
>> >
>> > --- In QuadtoneRIP@yahoogroups.com, Michael King <drmrking@> wrote:
>> > >
>> > > Seanh,
>> > >
>> > > ok so just to confirm - you are printing the 21 x 4 random target from
>> > the
>> > > QTR eye-one folder - correct?
>> > > Without changing its size or anything else - correct?
>> > >
>> > > then you load the 24 x 4 random txt file into measure tool and select
>> > "mode:
>> > > strip without gaps".
>> > > Then starting at the top left of the target where it says "Beg" you scan
>> > the
>> > > target smoothly from left to right for one line and the come back to the
>> > > beginning of the next line and scan from left to right again etc.
>> > >
>> > > Note you must start the scan on the white paper before the target line
>> > and
>> > > end on the white paper after the target line.
>> > >
>> > > Mike
>> > >
>> > >
>> > >
>> > > On 26 August 2011 21:13, spsguru <spsguru@> wrote:
>> > >
>> > > > **
>> > > >
>> > > >
>> > > > Mike
>> > > >
>> > > > Thank you for the tip.
>> > > >
>> > > > I did install measure. After multiple tries I keep getting the out of
>> > order
>> > > > error using the 21x4 patch
>> > > >
>> > > > When I look at the sampled strip just prior to export it looks like the
>> > > > printed strip so I think I am measuring then right patch
>> > > >
>> > > > But like I said after about 6 tries I keep getting the error
>> > > >
>> > > > Any ideas how to get past this?
>> > > >
>> > > > Thank you
>> > > > Sean
>> > > >
>> > > > --- In QuadtoneRIP@yahoogroups.com, Michael King <drmrking@> wrote:
>> > > > >
>> > > > > I don't think iprofiler supports spot measurements. You need the old
>> > > > xrite
>> > > > > "measuretool". It comes as part of the discontinued profilemaker5
>> > > > download,
>> > > > > and the features you need work without a dongle (i.e. free). You can
>> > get
>> > > > it
>> > > > > here ...
>> > > > >
>> > > >
>> > http://www.xrite.com/product_overview.aspx?ID=757&Action=support&SoftwareID=931
>> > > > >
>> > > > > I think you can choose what to install - so just install measuretool.
>> > > > >
>> > > > > Good luck.
>> > > > >
>> > > > > Mike
>> > > > >
>> > > > > On 26 August 2011 01:56, spsguru <spsguru@> wrote:
>> > > > >
>> > > > > > **
>> > > > > >
>> > > > > >
>> > > > > > Hi all
>> > > > > >
>> > > > > > I am new to creating icc profiles
>> > > > > >
>> > > > > > I just purchased i1 Pro Basic kit
>> > > > > >
>> > > > > > The software it comes with is i1 Profiler that automatically
>> > creates
>> > > > > > targets
>> > > > > >
>> > > > > > I cannot find a way to just get to the measuring device and take
>> > the
>> > > > spot
>> > > > > > measurements I think I need to for creation of ICC - or to load in
>> > the
>> > > > > > target the way the Roy's icc instructions dictate for the old
>> > software.
>> > > > > >
>> > > > > > Any help on creating icc profiles with i1 Pro basic kit would be
>> > > > > > appreciated
>> > > > > >
>> > > > > > thank you
>> > > > > > Sean
>> > > > > >
>> > > > > >
>> > > > > >
>> > > > >
>> > > > >
>> > > > > [Non-text portions of this message have been removed]
>> > > > >
>> > > >
>> > > >
>> > > >
>> > >
>> > >
>> > > [Non-text portions of this message have been removed]
>> > >
>> >
>> >
>> >
>>
>>
>> [Non-text portions of this message have been removed]
>>
>
>
>
>
> ------------------------------------
>
> Yahoo! Groups Links
>
>
>
>



-- 
Roy Harrington
roy@...
www.harrington.com

Attachments

Move to quarantaine

This moves the raw source file on disk only. The archive index is not changed automatically, so you still need to run a manual refresh afterward.