What version of PhraseAlator are you running? How do you have the Mode select pins wired/switched? What baud rate are you using to communicate with the SpeakJet? It defaults to 9600 baud and sometimes... needs to be reset. For normal operation (see page 2 of the Operator's Manual), M0 (mode select - pin 13) should be tied low (GND) and M1 (pin 12) should be tied high (+5V). To place it into demo mode, place +5 on M0. To reset (autodetect) the baud rate, put it into demo mode, then momentarily put M1 low. You should hear a sonar ping. Put M1 back to high. Once it has detected the baud rate, it will automatically go back into demo mode. Then, simply take it out of demo mode and all should work fine. I just noticed the schematic online doesn't show M1 (SpeakJet pin 12) tied to +5 through a resistor (1k should be fine). This pin must be tied high for normal operation. If left floating... it's probably confused as to what it's supposed to be doing. Let me know if this helps. Thanks, Brice http://www.SynthModules.com SynthModules PSIM Modules & SpeakJet Chips ----- Original Message ----- From: "djbrow54" <davebr@earthlink.net> To: <SynthModules@yahoogroups.com> Sent: Thursday, April 22, 2004 10:57 PM Subject: [SynthModules] PhrasAlator not talking to comm ports > I posted this also on the Speakjet group. I'm having the exact same > problem. I can talk to the speakjet in hyperterminal and can see the > data with a scope on the RS-232 pin 3. In PhraseAlator I see no data. > I had to install the MSCOMM32.OCX file in the \system32 and run > REGSVR32.EXE to register it. I am running WindowsXP Pro. > > Any other suggestions? > > Dave > > > --- In speakjet@yahoogroups.com, "Ken Griest" <posoup@w...> wrote: > > The problem is that it doesn't work with the PhraseALator > > software, which I found isn't sending data from my laptop's > > comm port. Hyperterminal and CCS's Serial I/O Monitor work, > > since I can type text and the speakjet will utter the correct > > allophones. > > > > I scoped my comm port's TX and RX lines and I see the data > > coming out from Hyperterminal and CCS. PhraseALator shows > > no activity, not with any comm port setting 1-4. > > > > I have all the neccessary VB ocx files installed, so I'm stuck. > > Has anyone seen this, or know what's wrong? Thanks in advance! > > > > -Ken > > > > Be sure to check out the primary Web site at: > http://www.SynthModules.com > > Yahoo! Groups Links > > > > >
Message
Re: [SynthModules] PhrasAlator not talking to comm ports
2004-04-23 by Brice D. Hornback
Attachments
- No local attachments were found for this message.