No idea what it is,- but I confirm, the test routines won�t run in a AKAI S-1100, OS v4.3 and 32 MB RAM. My fully working S-1100 shows exactly this "bug" ! I have a 2nd S-100 w/ a lower OS installed (typing from my head it might be v 1.3) and all the hardware test routines run fine w/ 32MB RAM. I also have to mention, positive test results don�t mean the sampler is fully functional. My 2nd S-1100, running all the test routines fine, has a fault I�ve never found up today. It loads samples, editing of samples and programs as well as all other operations w/ front panel controls and display work. But there�s simply no sound except a very low level click, audible w/ earphones only when pressing a key to play a sample or program or using the play button on the samplers front panel. But all the test routines are perfect incl. DAC, converters and memory cards. I also have the digital I/O (IB-104) board installed in both machines. Meanwhile I recognized by random, if I hit a specific parameter of the FX (card),- it freezes the machine. Am 28.12.2011 19:49, schrieb Gower Ramsey: > > > Hi all, > > I get white noise distortion added to the samples on long release > keygroups when more then 2 notes are played, is this a DAC calibration > problem? > I've gone through the service manual but can't get the hardware test > mode to activate, I'm on a S1100 v4.3 with 32mb memory. > > any advice would be appreciated > > Thanks > > Gower > > >
Message
Re: [akaiS1000S1100Samplers] Re: white noise digital distortion problem
2011-12-28 by PeWe
Attachments
- No local attachments were found for this message.