Akai S1000 / S1100 samplers group photo

Yahoo Groups archive

Akai S1000 / S1100 samplers

Index last updated: 2026-04-28 23:15 UTC

Message

Re: [akaiS1000S1100Samplers] S1100 & CD-ROM drive problems

2015-12-09 by Ewan Colsell

when I first tried to connect a cd-rom drive to my S1000hd I
discovered that the SCSI card was terminated on the inside. I had to
remove the terminating resistor packs before it would work with
external.SCSI devices. and use an external terminator after the cdrom
drive.

both ends of a SCSI chain must be terminated, always.

ewan.

On 08/12/2015, evg2003@... [akaiS1000S1100Samplers]
<akaiS1000S1100Samplers@yahoogroups.com> wrote:
> I have AKAI S1100 OS 4.3 and 4x SCSI CD-ROM drive, when I select hard drive
> in LOAD option (set SCSI ID to 4 like in CD drive) - I see message Hard
> drive does not read... this CD drive tested in other samplers and works ok,
> I opened S1100 and see 50-pin connector in the end of SCSI board - maybe
> SCSI board are not terminated? also how I coonect internal hard drive there
> for testing?
>
>
>


-- 
http://www.ewancolsell.com/