Akai S1000 / S1100 samplers group photo

Yahoo Groups archive

Akai S1000 / S1100 samplers

Index last updated: 2026-04-28 23:15 UTC

Message

Re: [akaiS1000S1100Samplers] S1100 & CD-ROM drive problems

2015-12-09 by PeWe

AKAI S-1000 / S-1100 default SCSI ID is #6 !
Can\ufffdt be changed.
Set your drives to any other than ID #6,- so #0 - #5 and/or #7

When you have a working SCSI card in your S-1000 / S-1100 don\ufffdt even think about internal termination, I never did and I\ufffdm an old fart and 1st owner.

You have a working drive, a 50-pin Centronics cable you plug between drive and sampler and a 50-pin Centronics terminator plug (passive or active,- active is w/ LED) you plug on the 2nd SCSI connector your CD-ROM drive-case offers.
Now do the ID settings ...
That\ufffds all.

Download manuals HERE

P.


Am 09.12.2015 um 10:51 schrieb evg2003@... [akaiS1000S1100Samplers]:
\ufffd

Where is located those terminators? I didn't find any manuals how install hard drive or SCSI board description... I think my CD drive terminated in the end otherwise it could not work with other samplers.
I changed ID number to 5 in CD-ROM and now S1100 read CD disk successfully, I guess that 5 is default number when system start and scan for ext hard drive... owner's manual says when install internal HD the number must be 5, so I connected external CD drive to SCSI card and it works only with ID 5.